| Model |
CA-527 |
| Measurement area |
Ø 27 mm |
| Accuracy guaranteed measurement distance |
30 ± 5 mm |
| Luminance |
Accuracy guaranteed luminance range*7 |
0.0001 to 10,000 cd/m2 |
| Accuracy (for white)*1,*3 |
> 0.0001 cd/m2 |
± 9 % |
| > 0.001 cd/m2 |
± 2 % |
| > 0.01 cd/m2 |
± 1.5 % |
| > 0.1 cd/m2 |
± 1.5 % |
| Repeatability (2σ)*1 |
|
| > 0.0001 cd/m2 |
10% |
| > 0.001 cd/m2 |
1% |
| > 0.01 cd/m2 |
.30% |
| > 0.1 cd/m2 |
0.12% |
| >1 cd/m2 |
0.12% |
| Chromaticity |
Accuracy guaranteed luminance range*7 |
0.0001 to 10,000 cd/m2 |
| Accuracy (for white)*1,*3 |
> 0.001 cd/m2 |
± 0.003 |
| > 0.01 cd/m2 |
± 0.002 |
| > 0.1 cd/m2 |
± 0.002 |
| Repeatability (2σ)*1 |
AUTO |
| > 0.001 cd/m2 |
0.003 |
| > 0.01 cd/m2 |
0.0009 |
| > 0.1 cd/m2 |
0.0004 |
| > 1 cd/m2 |
0.0002 |
| Flicker (CA-310 Mode) *6 |
Flicker (Contrast) |
Measurement luminance range*7 |
0.5 to 10,000 cd/m2 |
| Measurement target (Flicker frequency) |
0.25 to 65 Hz |
| Accuracy |
30 Hz, AC/DC 10% sine wave |
± 0.3% |
| 60 Hz, AC/DC 10% sine wave |
± 0.3% |
| Repeatability (2σ) |
20 to 65 Hz, AC/DC 10% sine wave |
0.3% |
| Flicker (JEITA) |
Measurement luminance range*7 |
0.5 to 10,000 cd/m2 |
| easurement target (Flicker frequency) |
.42 to 65 Hz |
| Accuracy |
30 Hz, AC/DC 4% sine wave |
±0.35 dB |
| 30 Hz, AC/DC 1.2% sine wave |
± 0.3% |
| Repeatability (2σ) |
30 Hz, AC/DC 4% sine wave |
0.1 dB |
| 30 Hz, AC/DC 1.2% sine wave |
0.3 dB |
| Waveform |
Measurement luminance range*7 |
0.1 to 10,000 cd/m2 |
| Sampling frequency |
200 kHz Changeable |
| Repeatability (2 σ) |
Lv: 0.1 cd/m2, fs: 3 kHz, fc: 1 kHz |
1.80% |
| VRR-Flicker |
Measurement luminance range*7 |
0.5 to 10,000 cd/m2 |
| Sampling frequency |
200 kHz Changeable |
| Measurement target (Flicker frequency) |
0.25 to 240 Hz |
| Accuracy |
1 to 120 Hz, AC/DC 10% sine wave |
± 0.3% |
| Repeatability (2 σ) |
1 to 120 Hz, AC/DC 10% sine wave |
0.30% |
| XYZ (Wide Frequency Mode) *6 |
Flicker (Contrast) |
Measurement luminance range*7 |
0.5 to 10,000 cd/m2 |
| Measurement target (Flicker frequency) |
0.25 to 200 Hz |
| Accuracy (for white)*1,*3 |
30 Hz, AC/DC 10% sine wave |
± 1.5 % |
| 60 Hz, AC/DC 10% sine wave |
± 2.2 % |
| Repeatability (2σ) |
20 to 65 Hz, AC/DC 10% sine wave |
1.6% |
| Flicker (JEITA) |
Measurement luminance range*7 |
0.5 to 8,500 cd/m2 |
| Measurement target (Flicker frequency) |
0.42 to 200 Hz |
| Accuracy (for white)*1,*3 |
30 Hz, AC/DC 4% sine wave |
± 0.35 dB |
| 30 Hz, AC/DC 1.2% sine wave |
± 0.35 dB |
| Repeatability (2σ) |
30 Hz, AC/DC 4% sine wave |
0.4 dB |
| 30 Hz, AC/DC 1.2% sine wave |
1.4 dB |
| Waveform |
Measurement luminance range*7 |
0.1 to 10,000 cd/m2 |
| Sampling frequency |
3 kHz Changeable |
| Repeatability (2 σ) |
Lv: 0.1 cd/m2 |
13% |
| Lv: 1 cd/m2 |
1.40% |
| Accuracy guaranteed measurement speed *4 |
Lvxy |
AUTO |
1 time/sec (> 0.0001 cd/m2) |
| 5 times/sec (> 0.015 cd/m2) |
| 20 times/sec (> 0.2 cd/m2) |
| Flicker (Contrast) |
20 times/sec |
| Flicker (JEITA/VESA) |
0.5 times/sec (at 1 Hz pitch), 2.5 times/sec (at 10 Hz pitch) |
| VRR-Flicker |
Sampling frequency: 3 kHz |
0.7 times/sec (at 1s Exp.) |
| Measurement target (Vertical synchronization frequency) |
0.5 to 240 Hz (luminance and chromaticity) |
| Power supply |
DC 5 V (input from USB bus power line or RS communication connector) |
| Operating temperature/humidity range*5 |
10 to 35°C, relative humidity 85% or less with no condensation |
| Storage temperature/humidity range |
0 to 45°C, relative humidity 85% or less (at 35°C) with no condensation |